The minimum necessary radial load applied to a radial needle bearing can be estimated using the following formula:
Frm = 0.02 C
The minimum necessary axial load for angular contact ball bearings can be calculated using the following formula:
In the middle
Frm = lowest radial load, kilonewton
Fam = lowest axial load, kilonewton
C = basic dynamic load rating (see product table), kilonewton
C0 = basic static load rating (see product table), kilonewton
Dm = average diameter of the bearing
= 0,5 (d + D), mm
n = speed, rev / min
Higher loads are required even at low temperatures or when the viscosity of the lubricant is very high. The weight of the components supported by the bearing plus the external force generally exceeds the necessary minimum load. If this is not the case, additional radial and/or axial loads must be applied to the needle/angular contact ball bearings.